LeYang Co., Ltd.

Leqing Medical Management System has two vulnerabilities affecting versions 2.4.2.8 to 2.5.1.9; update to 2.5.2.0 or later immediately.

Event Description

According to the TWCERT TVN announcement, the Leqing Medical Management System has 2 vulnerabilities. The TVN ID is TVN-202608007, corresponding to CVE-2026-78685 and CVE-2026-82181, with a public disclosure date of 2026-08-25.[1]

Among them, CVE-2026-78685 is labeled Remote Code Execution, with a CVSS score of 8.8 (High); CVE-2026-82181 is classified as Sensitive Data in URL, with a CVSS score of 5.5 (Medium).[1]

The announcement states that the affected products are Leqing Medical Management System versions 2.4.2.8 through 2.5.1.9, and the remediation is to update to version 2.5.2.0 or later.[1]

Technical Analysis

The core risk of CVE-2026-78685 is that an unauthenticated remote attacker can use a specially crafted HTML page to execute arbitrary operating system commands.[1]

From the CVSS:3.1 vector AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H, this vulnerability is network-reachable, low in attack complexity, requires no privileges, but does require user interaction.[1]

CVE-2026-82181 is classified as Sensitive Data in URL, and the announcement explains that an unauthenticated remote attacker can obtain sensitive information by viewing the victim's browser history or logs.[1]

Although the two vulnerabilities differ in type, both indicate high-risk characteristics of sensitive data exposure and remote exploitability.[1]

Impact Scope

The impact scope of this issue clearly covers Leqing Medical Management System versions 2.4.2.8 through 2.5.1.9.[1]

Because the announcement does not provide more detailed attack chains, exploitation conditions, or affected module information, in practice version inventory and risk classification should be prioritized.[1]

Protection Recommendations

The first priority is to immediately upgrade Leqing Medical Management System to version 2.5.2.0 or later, which is the remediation explicitly provided in the announcement.[1]

Second, any URL that may carry parameters should be reviewed to avoid sensitive data appearing in browser history or system logs.[1]

Third, if the system cannot be upgraded immediately, access controls and log monitoring should be strengthened so abnormal requests or suspicious behavior can be detected early.[1]

Fourth, host-level integrity should be checked in parallel to reduce the persistence risk after a successful Remote Code Execution attack.[1]

Fifth, awareness should be raised among users and operations staff, especially regarding links or abnormal pages from unknown HTML pages, because the announcement has already indicated that a specially crafted HTML page may be the attack trigger surface.[1]

Overall, this announcement shows that the Leqing Medical Management System has both an RCE vulnerability that can lead to arbitrary command execution and a URL exposure issue that can cause sensitive data leakage.[1]

5-Step Remediation Checklist

  • Confirm whether all Leqing Medical Management System versions in the environment fall within 2.4.2.8 to 2.5.1.9.
  • Immediately plan to update to version 2.5.2.0 or later.
  • Check whether sensitive data has been placed in URLs, browser history, or system logs.
  • Strengthen access control for the management interface and external exposure to reduce the risk of being tricked into opening a specially crafted HTML page.
  • After updating, continue monitoring for abnormal requests, system integrity, and suspicious execution behavior.

References

  • TWCERT TVN: Leqing Medical Management System - 2 Vulnerabilities Exist